Electronic Lubrication Timers

LUBRICATION ELECTRICAL TIMER

Electronic timers are used to maintain the Lubrication cycle in automatic single shot Lubrication Units. It is basically ON – OFF timer with following technical specifications.

Power Supply 220 V AC + – 10%, 50 Hz
Operating Temperature 0-55° C
Maximum Power Consumption 2.0 VA
Control Action On Off Type.
OutPut 220 V AC
Start Automatic On output when power is turned On
Application provides On – Off action of Lubricator Motor

In case arrangements of contactor are not possible, ETC-5 can be used. It is complete arrangement with inbuilt timer, contactor and indication of low oil in the pump thru float switch. This device is very useful in THE ADVERSE CONDITIONS AS IT EVEN DOESN’T ESQUIRE NEUTRAL IN THE INPUT SUPPLY.

  • Suitable for direct running of Single phase motors of Lubrication Units: LAU-03 SFS, LAU-03SFT, LDU-03S/ST
  • Suitable for 3 phase Units where pressure switch is not present such as LAU-03 FS, LAU-03FS, LAU-08FS. However a contractor is to be used in this case.

LUBRICATION ELECTRICAL CONTROLLER

Model: LTS-1002XP

Wiring diagram with control voltage 220V and contactor coil voltage 220V
In similar way control voltage 220V can also be used. We can interlock machine by controller.